MVE HE 1536P-190 Basic
For Vapor Phase Storage Holds 36,400 Vials in Boxes
The MVE 1500 Series -190° C freezers provide stable cryogenic storage for up to 42,000 - 1.2 / 2.0 ml vials. These freezers provide maximum storage density and provide the industry's longest hold time.
Features:
- Dry sample storage
- -190°C top box temperature
- Lowest liftover height
- Largest LN2 capacity at vapor platform
- 2 tier folding step
- Optional Battery Backup
- Conforms to MDD 93/42/EEC, the Medical Device Directive for the EU. Freezer systems UL/C-UL Listed.
- TWO Year Parts Warranty • FIVE Year Vacuum Warranty
2024 List Price - $34,836.00 - Request quote for discounted pricing
Maximum Storage Capacity
• 1.2 & 2 ml Vials (Internally Threaded): 34,600
• Quantity of Large Racks - 100 cell boxes: 24
• Quantity of Mini Racks - 25 cell boxes: 16
• Number of Shelves per Rack: 13
Performance
• Temperature Range: -20°C, -150°
• LN2 Usage at -80°C: 9 L/Day
• Power Consumption (cont.): 8W
Unit Dimensions
• Neck Opening: 17.5" (445 mm)
• Useable Internal Height: 28.8" (732 mm)
• Inner Diameter: 38.5" (978 mm)
• Overall Height: 61.3" (1,556 mm)
• Door Width Requirement**: 42" (1,067 mm)
• Weight Empty*: 690 lb. (313 kg)
Blood Bag Capacities
• 791 OS/U Medsep (25 ml) - Total bags:3,080 - Bags/Frame: 7 - No. Frames: 440
• 4R9951 (50 ml) - Total bags: 1,488 - Bags/Frame: 6 - No. Frames: 248
• 4R9953 (250 ml) - Total bags: 812 - Bags/Frame: 4 - No. Frames: 203
• 4R9955 (500 ml) - Total bags: 608 - Bags/Frame: 4 - No. Frames: 152
• DF200 (200 ml) - Total bags: 496 - Bags/Frame: 4 - No. Frames: 154
• DF700 (700 ml) - Total bags: 256 - Bags/Frame: 4 - No. Frames: 64
* Without inventory
** Minimum width required for vessel to pass through opening. Footprint may vary. Contact Tech Service for detailed drawings.
TWO Year Parts Warranty • Five Year Vacuum Warranty
Conforms to MDD 93/42/EEC, the Medical Device Directive for the EU.Freezer systems UL/C-UL listed.
- 13384921 | Optional Magnetic Lid Lock Assembly
- 3911217 | Replacement Cap for Vacuum Plug
Maximum Storage Capacity
• 1.2 & 2 ml Vials (Internally Threaded): 34,600
• Quantity of Large Racks - 100 cell boxes: 24
• Quantity of Mini Racks - 25 cell boxes: 16
• Number of Shelves per Rack: 13
Performance
• Temperature Range: -20°C, -150°
• LN2 Usage at -80°C: 9 L/Day
• Power Consumption (cont.): 8W
Unit Dimensions
• Neck Opening: 17.5" (445 mm)
• Useable Internal Height: 28.8" (732 mm)
• Inner Diameter: 38.5" (978 mm)
• Overall Height: 61.3" (1,556 mm)
• Door Width Requirement**: 42" (1,067 mm)
• Weight Empty*: 690 lb. (313 kg)
Blood Bag Capacities
• 791 OS/U Medsep (25 ml) - Total bags:3,080 - Bags/Frame: 7 - No. Frames: 440
• 4R9951 (50 ml) - Total bags: 1,488 - Bags/Frame: 6 - No. Frames: 248
• 4R9953 (250 ml) - Total bags: 812 - Bags/Frame: 4 - No. Frames: 203
• 4R9955 (500 ml) - Total bags: 608 - Bags/Frame: 4 - No. Frames: 152
• DF200 (200 ml) - Total bags: 496 - Bags/Frame: 4 - No. Frames: 154
• DF700 (700 ml) - Total bags: 256 - Bags/Frame: 4 - No. Frames: 64
* Without inventory
** Minimum width required for vessel to pass through opening. Footprint may vary. Contact Tech Service for detailed drawings.
TWO Year Parts Warranty • Five Year Vacuum Warranty
Conforms to MDD 93/42/EEC, the Medical Device Directive for the EU.Freezer systems UL/C-UL listed.
- 13384921 | Optional Magnetic Lid Lock Assembly
- 3911217 | Replacement Cap for Vacuum Plug